The 1x2 HDMI Splitter that supports Full HD 3D & 4K*2K uses 1 HDMI source,accessing to 2 HDMI sinks. The Splitter allows 1 HDMI devices to be splitted easily to 2 HDMI compatible monitors or projectors. The Splitter can also be placed at the end of a long HDMI cable to regenerate the HDMI signal.
Supplier: 1) plastic injection molded parts
2) mould design and development
3) automotive plastic parts
4) auto electrical parts
5) industrial/automotive battery parts
6) plastic household products
7) gear moulding
8) over moulding
9) insert moulding
Buyer: 1) copper plated/tin plated terminals for auto electrical parts.
CIRCULLATION FAN Air cooling fans are used for maintaining good air circulation and temperature in poultry farms. Our 36 air circulating fans can be used for various applications, like poultry farms, industrial buildings etc., and providing high efficiency. These fans are available in both single phase and three phase motor option. 1.Grills are plastic coated and thick diameter wire gauge (2.5mm) is used, and the gap is maintained 15mm as per international quality standards to avoid human accidents and rate entering into the fan. 2. The blades are made of compounded plastic so less chances of bending and hence less breaking chances. 3. Motor is efficient and complete thermal protection and moisture proof. 4. The CFM of fan 13000 and minimum airflow of 8.5 meters/sec. 5. Minimum positive air throws of 50ft. When we say 50 Length in practically. 6. Easy installation &Zero Maintenance
Application :- These multi core flexible cables are used for wiring in control panels, machines and various electrical installations in dry and damp interiors specially under typical industrial environmental conditions. Features :- Manufactured from bright annealed 99.97% pure bare copper conductors, these cables offer low conductor resistance. These wires are insulated with a special grade PVC compound formulated and manufactured in-house. The tough robust outer PVC jacket protects it from oils, greases and various chemicals and abrasions, thereby giving long life and electrical safety. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C Sizes : 0.50 to 4.00 Sq. mm in 2 core to 19 cores & 6.00 to 120.00 Sq. mm in 3 core and 4 core. Color Codes : Black and Grey Outer Sheath 2 Core Cables - Red, Black 3 Core Cables - Red, Black & Green (for Earth) 4 Core Cables - Red, Yellow, Blue & Green (for Earth) 5 Core Cables - Red, Yellow, Blue, Black & Grey Specification : IS:694 Packing : In 90 meter coils, higher sizes in drums.
Application :- The Power Cables are used under ground as well as over head transmission of power in power plants, industries, projects and all other electrical installations. Features :- Manufactured from bright annealed 99.97% pure bare copper & aluminum conductors. These cables are insulated with PVC compound. Taped/Extruded inner sheath. Round steel wire / flat galvanised steel grip armoured. The inner & outer sheaths can be PVC, HR PVC, FRLS, HR-FRLS or FR depending upon the application and requirement. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C or +85�°C in HR PVC Power Cable Sizes : 1.50 Sq. mm to 400.00 Sq. mm in 2, 3, 3 & 4 core. Copper Control Cable Sizes : 1.50 Sq. mm, 2.50 Sq. mm up to 24 cores. Color Codes : 2 Core Cables - Red, Black 3 Core Cables - Red, Yellow & Blue 3 Core Cables - Red, Yellow, Blue & Black (for Neutral) 4 Core Cables - Red, Yellow, Blue & Black 5 Core Cables - Red, Yellow, Blue, Black & Grey 6 Core Cables & above - Adjacent cores are blue for reference and yellow for direction in each lay Black outer sheath Specification : IS:1554 (Part-1) Packing : 500 / 1000 meters on drums
Application :- The XLPE (Cross Link Poly Ethylene) Power Cables are used under ground as well as over head transmission of power in power plants, industries, projects and all other electrical installations. Features :- Manufactured from bright annealed 99.97% pure bare copper & aluminum conductors. These cables are insulated with XLPE compound. Taped/Extruded inner sheath. Round steel wire / flat galvanised steel grip armoured. The outer sheaths can be PVC, HR PVC, FRLS or FR depending upon the application and requirement. Technical Advantage of XLPE Insulation :- Higher current rating, higher short circuit rating (approx 1.2 times that of PVC), thermosetting in nature, higher insulation resistance (1000 times more than PVC cables), higher moisture resistance, better resistance to surge currents, low dielectric losses, better resistance to chemicals and corrosion, longer service life. Comparatively higher cable operating temperature 90�°C and short circuit temperature 250�°C. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +90�°C Power Cable Sizes : 1.50 Sq. mm to 400.00 Sq. mm in 2, 3, 3 Copper Control Cable Sizes : 1.50 Sq. mm, 2.50 Sq. mm up to 24 cores. Color Codes : 2 Core Cables - Red, Black 3 Core Cables - Red, Yellow & Blue 3 Core Cables - Red, Yellow, Blue & Black (for Neutral) 4 Core Cables - Red, Yellow, Blue & Black 5 Core Cables - Red, Yellow, Blue, Black & Grey 6 Core Cables & above - Adjacent cores are blue for reference and yellow for direction in each lay Black outer sheath Specification : IS:7098 (Part-1) Packing : 500 / 1000 meters on drums
ALTUS AL434 A DISHWASHER - 4 PROGRAMS
Type Universal USB charger socket Charging Port 2 Ports Connection Universal USB charger socket Warranty 1 Year Combination Charger Socket Outlet Voltage 12-24v Model Number DS2014 Design Style New China-Chic Product name 4.2A Car Cigarette Lighter Socket Splitter Dual USB Charger Material ABS Input Voltage 12V-24V USB output 4.2A Size 3.7*5.4*2.9cm/1.5*2.12*1.14inch LED Blue LED Waterproof grade IP65 Working temperature Min.-20 Celsius Degree, Max. 80 Celsius Degree
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".